DM2C-RS556
分類: DM2C系列 發(fā)布時間:21-12-28 瀏覽量:836
1、電氣指標
參數 | DM2C-RS556 | |||
最小值 | 典型值 | 最大值 | 單位 | |
輸出電流(峰值) | 2.1 | — | 5.6 | A |
電源電壓(直流) | 20 | 24/36 | 50 | V |
IO輸入電流 | 3 | — | 7 | mA |
IO輸入電壓 | 12 | 24 | 24 | V |
出廠默認電流 | 1 | A |
2、端子及撥碼說明
2.1?電源端子
端子號 | 圖示 | 管腳號 | 信號 | 名稱 |
CN1 | 1 | VDC | 電源正輸入端 | |
2 | GND | 電源地 |
2.2?電機繞組端子
端子號 | 圖示 | 管腳號 | 信號 | 名稱 |
CN2 | 4 | A+ | 電機線組A相正端 | |
3 | B+ | 電機線組B相正端 | ||
2 | A- | 電機線組A相負端 | ||
1 | B- | 電機線組B相負端 |
2.3?控制信號端子
端子號 | 圖示 | 管腳號 | 信號 | 輸入/輸出 | 名稱 |
CN4 | 1 | DI1 | 輸入 | 單端輸入DI1,12-24V有效,功能可配置,默認使能輸入 | |
2 | DI2 | 輸入 | 單端輸入DI2,12-24V有效,功能可配置,默認自定義 | ||
3 | DI3 | 輸入 | 單端輸入DI3,12-24V有效,功能可配置,默認自定義 | ||
4 | DI4 | 輸入 | 單端輸入DI4,12-24V有效,功能可配置,默認自定義 | ||
5 | DI5 | 輸入 | 單端輸入DI5,12-24V有效,功能可配置,默認自定義 | ||
6 | DI6 | 輸入 | 單端輸入DI6,12-24V有效,功能可配置,默認自定義 | ||
7 | DI7 | 輸入 | 單端輸入DI7,12-24V有效,功能可配置,默認自定義 | ||
8 | COMI | 輸入 | 輸入信號公共端 | ||
9 | DO1 | 輸出 | 單端輸出DO1,最大輸出電流100mA,輸出功能可配置,默認通用輸出功能 | ||
10 | DO2 | 輸出 | 單端輸出DO2,最大輸出電流100mA,輸出功能可配置,默認通用輸出功能 | ||
11 | DO3 | 輸出 | 單端輸出DO3,最大輸出電流100mA,輸出功能可配置,默認通用輸出功能 | ||
12 | COMO | 輸出 | 輸出信號公共端 |
注:
(1)、DI1出廠默認為使能輸入,常閉信號,驅動器上電后電機默認即為鎖軸狀態(tài)。
(2)、線徑≥0.12mm2? (AWG24-26) 。建議采用雙絞屏蔽電纜,電纜長度盡可能短,建議不超過3米。盡量遠離動力線布線,防止干擾串入。請給相關線路中的感性原件(如線圈)安裝浪涌吸收元件;直流線圈反向并聯續(xù)流二極管,交流線圈并聯阻容吸收回路。
2.4 RS485總線接口端子
端子號 | 圖示 | 管腳號 | 信號 | 名稱 |
CN4 | A-1 | RS485+ | 485總線數據正端 | |
A-2 | RS485- | 485總線數據負端 | ||
A-5 | GND | 電源地 | ||
A-6 | GND | 電源地 | ||
B-1 | RS485+ | 485總線數據正端 | ||
B-2 | RS485- | 485總線數據負端 | ||
B-5 | GND | 電源地 | ||
B-6 | GND | 電源地 | ||
其他引腳 | NC | 共16腳,其他沒用到的保留 |
注: 以上定義為驅動器側接口定義。在網絡的最后一臺設備處,通常需要并聯一個120Ω的電阻,對于我方驅動器,直接將SW8撥到ON即可。
2.5?撥碼開關
驅動器采用八位撥碼開關設定細分精度、動態(tài)電流、靜止半流以及實現電機參數和內部
調節(jié)參數的自整定。詳細描述如下:
通訊地址:(5位撥碼共同設定,off=1,on=0)
通訊地址 | SW1 | SW2 | SW3 | SW4 | SW5 |
1(默認) | on | on | on | on | on |
1 | off | on | on | on | on |
2 | on | off | on | on | on |
3 | off | off | on | on | on |
4 | on | on | off | on | on |
5 | off | on | off | on | on |
6 | on | off | off | on | on |
7 | off | off | off | on | on |
8 | on | on | on | off | on |
9 | off | on | on | off | on |
10 | on | off | on | off | on |
11 | off | off | on | off | on |
12 | on | on | off | off | on |
13 | off | on | off | off | on |
14 | on | off | off | off | on |
15 | off | off | off | off | on |
16 | on | on | on | on | off |
17 | off | on | on | on | off |
18 | on | off | on | on | off |
19 | off | off | on | on | off |
20 | on | on | off | on | off |
21 | off | on | off | on | off |
22 | on | off | off | on | off |
23 | off | off | off | on | off |
24 | on | on | on | off | off |
25 | off | on | on | off | off |
26 | on | off | on | off | off |
27 | off | off | on | off | off |
28 | on | on | off | off | off |
29 | off | on | off | off | off |
30 | on | off | off | off | off |
31 | off | off | off | off | off |
注:SW1-SW5全為on時,可通過上位機或者RS485通訊設置地址。
當節(jié)點處于默認狀態(tài)時,也可通過軟件進行節(jié)點地址設定。
波特率設置:
波特率 | SW6 | SW7 |
115200 | on | on |
38400 | off | on |
19200 | on | off |
9600 | off | off |
注:SW6-SW7全為off時,可通過上位機或者RS485通訊設置波特率。
終端電阻選擇:
SW8=ON?:終端電阻有效?SW8=OFF?:終端電阻無效(默認)
2.6?儲存和安裝環(huán)境
表2.1?驅控一體系列驅動器存儲及安裝環(huán)境 | ||
保存溫度 | -20℃~65℃ | |
防護等級 | IP20 | |
使用環(huán)境 | 場合 | 不能放在其它發(fā)熱的設備旁,要避免粉塵、油霧、腐蝕性氣體,濕度太大及強振動場所,禁止有可燃氣體和導電灰塵; |
溫度 | 0~50℃ | |
濕度 | 40~90%RH | |
振動 | 10~55Hz/0.15mm |